Product PDF: Toughened Glass Insulator
The electrical behavior in overhead lines operation depends primarily on the external insulation.
An insulator should have enough electro-mechanical strength to support not only the conductor weight, but also the stresses by wind, lighting and flashover under any humidity condition.
The glass insulators for overhead lines are manufactured ...

Product PDF: Disconnect Switch
For manual switching of overhead lines on electrical distrubution systems up to 38 KV.
Its design allows for application as a distribution switch or a substation switch.
Rated for 6330 or 1,250 amps continuous, 25,000 and 38,100 momentary amps sym 3 seconds short-time withstand current.
They are according to CFE-V4200-25/97 ...

Product PDF: Dead End Insulator
Dead-end insulators for overhead lines.
Leakage current surge suppression due to high level of hydrophobicity of silicone rubber.
Aging evaluation at 5000 h in salt fog
Better performance in polluted areas
Light weight for handling and installation
The core rod of insulator is made of a fiberglass that has excellent electrical ...

Product PDF: Cutout Fuse
The cutout fuse is used in distribution from 15 KV to 27 KV, with nominal current of 100 amps and interruption currents from 8, 10 and 12 KA asymmetrics, to protect transformers, capcior banks and distribution lines against overloads and short-circuit currents.
The cutout fuse was developed to ...

Product PDF: UF-B
Applications
Type UF-B cable is generally used as feeder to outside post lamps, pumps and other loads or apparatus fed from a distribution point in an existing building as specified in the National Electrical Code. UF-B cable may be underground, including direct burial. Multiple conductor UF-B cable may be ...

Product PDF: SE-U
Applications
For above ground electrical service use from the electric utility power service point to the meter or service entrance panel. Under special conditions as permitted, the NEC Type SE Style U can be used for interior wiring as branch circuits to ranges, ovens, cooking units or clothes dryers. This cable ...

Product PDF: SE-R
Applications
For above ground electrical service use from the electric utility power service point to the meter or service entrance panel. Under special conditions as permitted, the NEC Type SE Style R can be used for interior wiring as branch circuits to ranges, ovens, cooking units or clothes dryers. ...

Product PDF: XHHW-2
Applications
Type XHHW-2 conductors are primarily used in conduit or other recognized raceways for services, feeders, and branch circuit wiring, as specified in the National Electrical Code®. Type XHHW-2 conductors may be used in wet or dry locations at temperatures not to exceed 90°C. Voltage rating for XHHW-2 ...

Product PDF: NM-B
Applications
Type NM-B (Nonmetallic-sheathed Cable) may be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C (with ampacity limited to that for 60 degrees C conductors) as specified in the National Electrical Code. NM-B cable is primarily used in ...

Bare Copper Conductor.
Solid and Stranded
Product PDF: Bare Copper
Applications
Solid and stranded (classes AA and A) bare copper are suitable for overhead transmission and distribution applications. Stranded conductor of greater flexibility (classes B and C) are suitable for uninsulated hook up, jumpers, and grounds in electrical construction.
Specifications
Bare copper wire and cable meets ...

Product PDF: THHN/THWN-2
Applications
Type THHN/THWN conductors are primarily used in conduit for services, feeder, and branch circuits in commercial or industrial applications as specified in the National Electrical Code®.
When used as type THHN or TWN75, conductor is suitable for use in dry locations at temperatures not to exceed 90°C.
When used as ...

Product PDF: TFFN
Applications
Cable type TFFN or MTW may be used as fixture wire, machine tool wiring.
May be installed in conduit, duct, or other recognized raceways in wet or dry locations. Small diameter of the wire permits additional circuits or larger conductors without exceeding maximum fill limitations.
When used as Type TFFN, conductor ...

Product PDF: MC Cable
Applications
Type MC Cable is suitable for use as feeder and service power distribution in commercial, industrial, institutional, and multi-residential buildings; power, lighting, control, and signal circuits; fished or embedded in plaster; concealed or exposed installations; environmental air-handling spaces per NEC 300.22(C); Places of Assembly per NEC 518.4 ...